Any processor below can be networked together in a plug-and-play fashion to create a fully expandable system by using Continental's CardAccess 195/295/495/200NT host software (Windows 95/98/NT platforms) designed for use on a compatible PC.
Continental's family of Controllers provides fully true distributed processing, capable of performing all Access Control functions for one to eight doors. Any member of this family (Superterm ®, Smarterm ®, Miniterm ® and Microterm ®) may be networked together in a plug-and-play fashion to create a fully expandable system by using Continental's CardAccess ® 495 host software (a Windows ® 95 platform) designed for use on a compatible PC.
Our controllers can use virtually all types of card reading technologies without the need for additional interface boards or modules. Controllers can store multiple badge formats in memory, allowing for use with existing card populations and readers. For efficiency, each controller's memory can be configured to meet on-site requirements. The size of the transaction buffer and card holder database may be adjusted from the host PC to tailor the memory requirements to the specific application.
Continental's controllers automatically up-load transactions as they occur and may also communicate with the host PC using standard voice-grade telephone lines and external modems. This dual dial-up capability allows each controller to store transactions and up-load automatically when memory approaches capacity or a priority alarm occurs (user-programmed). The host PC may also periodically dial a controller to maintain the system integrity.
|
CONTINENTAL
ACCESS CONTROL CONTROLLERS
|
|
|
| |
Micro
MICROTERM®
|
Mini
MINITERM®
|
Smart
SMARTERM®
|
Super
SUPERTERM®
|
| CAPACITIES |
|
|
|
|
| Card
Capacity |
Up
to 1,000 |
Up
to 3,000 |
2,000
to 100,000 |
20,000
to 200,000 |
| Card Reader Capacity |
2 |
2 |
4 |
8 |
| Keypad
Capacity |
1 |
2 |
4 |
8 |
| Duress Keypad |
Yes |
Yes |
Yes |
Yes |
| Number
of Doors |
1
to 2 |
2 |
4 |
4
or 8 |
| Transaction Bufer
Capacity |
Up to 1000 |
Up to 1000 |
1000 (up to 50,000) |
1000(up to 50,000) |
| Memory
RAM (with expansion) |
32k |
64k |
56k
(up to 2 Meg) |
128k
(up to 2 Meg) |
| Monitored Points
(inputs-linked) |
2 supervised |
8 supervised |
16 unsupervised
Expand to 48 (4x8 points)
or to 64 supervised (4x16 points) |
24 Supervised
Expand to 72 (3x16 points)
or to 24 unsupervised (3x8 points) |
| Output
Relays - Form C (linked) |
3 |
5 |
9 |
17 |
| Relay Expansion
- Form C (Opt) |
-- |
-- |
73 |
65 |
| Timed
Zones |
128 |
128 |
128 |
128 |
| Holidays |
50 |
50 |
50 |
50 |
| Link
Programs |
64 |
64 |
64 |
64 |
| Battery Backup |
4 to 6 hrs (Opt) |
5 to 6 hrs (std |
4 to 6 hrs (std) |
4 to 6 hrs (std) |
| |
|
|
|
|
| FUNCTIONS &
FEATURES |
All Continental
Controllers come complete with heavy duty sheet
metal enclosures with the line cords, ready for
installation. |
| "Learns"
all card encoding technologies |
Yes |
Yes |
Yes |
Yes |
| Anti-Passback |
Yes |
Yes |
Yes |
Yes |
| Fuse
Protected Strike Outputs |
-- |
-- |
-- |
2Amps
(10A Max.) |
| Downloadable Firmware |
-- |
-- |
-- |
Yes |
| Diagnostic
LEDs |
-- |
Yes |
Yes |
Yes |
| Tamper Alarm |
Yes |
Yes |
Yes |
Yes |
| Transient
Protected |
Yes |
Yes |
Yes
(polling only) |
Yes |
| Battery Charging
Output |
-- |
Yes |
Yes |
Yes |
| Printer |
Serial |
-- |
Serial
|
Serial |
| |
|
|
|
|
| SECIFICATIONS |
|
|
|
|
| Communication:
Protocol |
RS422/232 |
RS422/232 |
RS422/232/485 |
RS422/232/485 |
| Baud Rate |
12000/ 24000/ 48000/ 96000
bps |
12000/ 24000/ 48000/ 96000
bps |
12000/ 24000/ 48000/ 96000
bps |
12000/ 24000/ 48000/ 96000
bps |
| Auxillary
Serial Ports |
-- |
1C
(Master Only) |
RS232
(two) |
Rs232
(two) |
| Output Relay Contacts |
3A@
24VDC/AC |
3A@
24VDC/AC |
3A@
24VDC/AC |
3A@
24VDC/AC |
| Power
Supply Voltage |
12VDC |
120/230VAC |
120/230VAC |
120/230VAC |
Current Draw
(with all expansion & Specified accessories) |
200mA |
500mA
@ 120VAC |
750mA
@ 120VAC |
800mA
@ 120VAC |
| Reader
Supply Power (per panel) |
100mA |
200mA
@ 5VDC |
200mA
@ 5VDC |
800mA
@ 5VDC |
| Compliances |
UL294,
UL1950 & UL1076 |
UL294,
UL1950 & UL1076 |
-- |
UL294,
UL1950 & UL1076 |
| |
|
|
|
|
|